LG Washers

Error Code FE

Overflow Error — water level has exceeded safe limit

Moderate

Address soon - your appliance may not work properly

What This Means

Inlet valve leaking or failing open; Drain hose not positioned at correct height (must be 0.9-1.2 m above floor); Blockage or air leak in the hose between tub and pressure switch; Air leakage at air hose connector on outer tub

How to Fix

  1. 1

    In service mode, check if water level frequency is over 21.0 kHz; if not, check AIR CHAMBER and tube for clogs

  2. 2

    If frequency is over 21.0 kHz, check whether inlet valve activates when power is NOT applied

  3. 3

    If inlet valve opens without power command, replace INLET VALVE ASSEMBLY

  4. 4

    If inlet valve works correctly but error persists with power applied, replace MAIN PCB ASSEMBLY

  5. 5

    Ensure drain hose is positioned 0.9-1.2 m (36-48 inches) above floor

  6. 6

    Replace pressure sensor switch if tube/chamber is clear but FE persists

This Error Applies To

LG WT1501CW Series Washers

Service manual exact match: WT1501CW

Need more help with your LG washers?