Error Code FE
Over Flow Error - Water level too high
Moderate
Address soon - your appliance may not work properly
Also displayed as: FE
What This Means
Air chamber or pressure tube clogged — water level frequency under 21.0 kHz in service mode; Inlet valve leaking when power is not applied; PCBA commanding inlet valve continuously; PCBA fault
How to Fix
- 1
If water level frequency is under 21.0 kHz: Check air chamber and tube (clogged)
- 2
If segment is displayed under 10: replace the PCBA
- 3
If inlet valve runs continuously with power not applied: replace the inlet valve assembly
- 4
If inlet valve runs continuously only when power is applied: replace the main PCB assembly
This Error Applies To
LG WT7700H Series Washers (2015) (2015–present)
Related Error Codes
Door Lock Failure - Lid lock mechanism failed to lock
Drain Error - Water not draining
Motor Obstruction Error - Foreign object caught between wash plate and basket
Inlet Error - Water not filling or filling too slowly
Pressure Sensor Error - Water level pressure sensor fault
Door/Lid Lock Error - Lid lock failed to detect closed position
Unbalance Error - Load is unbalanced during spin
Thermistor Error - Water temperature sensor fault