Error Code 4C
The dishwasher is not getting enough water to run
Moderate
Address soon - your appliance may not work properly
Also displayed as: 4C
What This Means
Water supply pressure is low; Water supply valve is closed; Aqua stop is out of order; Foreign material in Water Supply Line or Water Valve filter; Water Valve connector disconnected; Water Valve coil not conductive; Main PBA defect; Power Relay error
What actually causes this:
The water supply valve under the sink is turned off, the water line is kinked, or the inlet filter is clogged with debris
First Thing to Check
Make sure the water supply valve under your kitchen sink is fully open and that no one has turned off the water to your home
Parts Involved
How to Fix
- 1
1. Check whether the faucet is open
- 2
2. Check whether the water supply has been cut off
- 3
3. Check whether any foreign material is in the Water Supply Line and the Water Valve filter — remove foreign material, clean filter with a brush
- 4
4. Check the connection for the Water Valve connector — reconnect
- 5
5. Check whether the coil in Water Valve is conductive (remove connector before measuring) — Normal: approx. 990 ohms +/- 10% (890-1089 ohms)
- 6
6. Check whether the water supply stops after water is supplied for 1 minute — check water supply pressure (> 1.0 bar). If faulty, replace Water Valve
- 7
7. Check whether the Water Valve is operating normally in the Main PBA — check Water Valve Relay: voltage between Blue wire (Number 6) of CN401 and Red wire of CN101 connector. Normal: 110-120V while operating
- 8
8. Check the Power Relay
This Error Applies To
Samsung DW80B7070A Series Dishwashers (2023) (2023–present)
Related Error Codes
The dishwasher cannot pump the dirty water out
The heating element is not warming the water properly
The water inside the dishwasher got dangerously hot
The hot air drying system is not heating up properly
The hot air drying system got dangerously overheated
The water temperature sensor is not reading correctly
The temperature sensor in the drying system is not reading correctly
A control panel button appears to be stuck or held down