Samsung Dishwashers2020–present

Error Code AC

The dishwasher's main control board and display board can't talk to each other

Moderate

Address soon - your appliance may not work properly

Also displayed as: No display

What This Means

Main PBA defective; Sub PBA defective; Communication connection between Main PBA and Sub PBA not properly connected; Wire harness damaged between boards

What actually causes this:

A power surge or loose wire connection disrupted communication between the control boards

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 60 seconds, then turn it back on

Parts Involved

Main PBASub PBAWire Harness

How to Fix

  1. 1

    1. Check connector between Main PBA and Sub PBA wire — reconnect

  2. 2

    2. Check connector between Sub PBA and Sub wire — reconnect

  3. 3

    3. Check for damaged or pinched wire harness

  4. 4

    4. If error persists after reconnecting all connectors, replace Sub PBA

  5. 5

    5. If error still persists, replace Main PBA

This Error Applies To

Samsung DW80R5061U Series Dishwashers (2020) (2020–present)

Service manual exact match: DW80R5061US/AAService manual exact match: DW80R5061UG/AAService manual exact match: DW80R5060US/AAService manual exact match: DW80R5060UG/AAService manual exact match: DW80T5040US/ACService manual exact match: DW80R5061UT/AA