Samsung Dryers2018–present

Error Code tC8

A fourth temperature sensor is reading abnormally

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC8

What This Means

Thermistor 4 resistance out of range (open or shorted); Damaged or disconnected thermistor wiring; PCB sensor circuit failure

What actually causes this:

One of the dryer's multiple temperature sensors has failed or its connection is loose.

First Thing to Check

Clean the lint screen and check the exhaust vent for blockages.

Parts Involved

Thermistor 4

How to Fix

  1. 1

    1. Measure Thermistor 4 resistance

  2. 2

    2. If resistance is out of range, replace Thermistor 4

  3. 3

    3. Check wiring between thermistor and main PCB

This Error Applies To

Samsung DV22N68 Series Dryers (2018) (2018–present)

Service manual exact match: DV22N685*H*Service manual exact match: DV22N6850HX/A2Service manual exact match: DV22N680*H*Service manual exact match: DV22N6800HW/AC