Samsung Dryers2018–present

Error Code tCA

A fifth temperature sensor is reading incorrectly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tCA

What This Means

Thermistor 5 resistance out of range (open or shorted); Damaged or disconnected thermistor wiring; PCB sensor circuit failure

What actually causes this:

One of the dryer's multiple temperature sensors has failed or become disconnected.

First Thing to Check

Clean the lint screen and check the exhaust vent for blockages.

Parts Involved

Thermistor 5

How to Fix

  1. 1

    1. Measure Thermistor 5 resistance

  2. 2

    2. If resistance is out of range, replace Thermistor 5

  3. 3

    3. Check wiring between thermistor and main PCB

This Error Applies To

Samsung DV22N68 Series Dryers (2018) (2018–present)

Service manual exact match: DV22N685*H*Service manual exact match: DV22N6850HX/A2Service manual exact match: DV22N680*H*Service manual exact match: DV22N6800HW/AC

Need more help with your Samsung dryers?