Samsung Dryers2020–present

Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Thermistor resistance out of range (open or shorted); Clogged lint screen restricting airflow; Restricted vent system causing abnormal temperatures; Faulty thermistor wiring

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

ThermistorLint ScreenExhaust Vent

How to Fix

  1. 1

    1. Check the thermistor resistance: should be 10K ohms at 25C (77F)

  2. 2

    2. Check for a clogged lint screen

  3. 3

    3. Inspect the exhaust vent system for restrictions or blockages

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DV45T3400 Series Dryers (2020) (2020–present)

Service manual exact match: DVE45T3400V/A3Service manual exact match: DVE45T3400P/A3Service manual exact match: DVE45T3400W/A3Service manual exact match: DVG45T3400V/A3Service manual exact match: DVG45T3400P/A3Service manual exact match: DVG45T3400W/A3