Error Code bC2
A button on the control panel is stuck or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: bC2
What This Means
Display PCB is loose; Display PCB is shorted; Stuck or shorted button on control panel
What actually causes this:
A button got stuck from moisture, spilled liquid, or just normal wear over time.
First Thing to Check
Press each button on the control panel a few times to see if any feel stuck or unresponsive.
Parts Involved
How to Fix
- 1
1. Check if any buttons on the control panel are stuck or jammed
- 2
2. Inspect the display PCB for signs of loose connection or short circuit
- 3
3. Check wiring between control panel and display PCB
- 4
4. If display PCB is confirmed faulty, replace it
Parts Commonly Needed for This Error
OEM part numbers confirmed by retailers
This Error Applies To
Samsung DV52J8 Series Dryers (2015) (2015–present)
Related Error Codes
The dryer thinks the door is open while running
Your dryer isn't heating properly or is overheating
Your dryer's temperature sensor isn't reading correctly
Your dryer is getting the wrong type of electrical power
The door switch isn't working properly
Your dryer is getting the wrong voltage from the outlet
The dryer's internal parts aren't communicating properly