Samsung Dryers2024–present

Error Code AC

The dryer's internal parts aren't communicating properly

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: AC

What This Means

Faulty Main PBA (main control board); Faulty Sub PBA (display board); Damaged or loose wire harness between Main PBA and Sub PBA; Corroded or pinched wiring in communication bus

What actually causes this:

A loose wire connection between the control board and display, or a power surge scrambled the electronics.

First Thing to Check

Unplug the dryer for 2 minutes, then plug it back in — this resets the electronics.

Parts Involved

Main PBA (Main PCB)Sub PBA (Display PCB)Wire Harness

How to Fix

  1. 1

    1. Check wire harness connection between Main PBA and Sub PBA for loose or damaged connectors

  2. 2

    2. Inspect wire harness for pinched, cut, or corroded wires

  3. 3

    3. Check the wire among the main sub PCBs — verify wiring is in good condition

  4. 4

    4. If wiring is intact, replace Sub PBA first (display board — more commonly at fault)

  5. 5

    5. If error persists after Sub PBA replacement, replace Main PBA

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DV52M7750 Series Dryers (2024) (2024–present)

Service manual exact match: DVE52M7750W/A3Service manual exact match: DVE52M7750V/A3Service manual exact match: DVE52M7750P/ACService manual exact match: DVG52M7750W/A3Service manual exact match: DVG52M7750V/A3Service manual exact match: DVE52M7750VService manual exact match: DVE52M7750PService manual exact match: DVG52M7750W+2 more