Error Code tC5
A secondary temperature sensor is giving bad readings
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC5
What This Means
Thermistor 2 resistance out of range (open or shorted); Clogged lint screen restricting airflow; Restricted vent system causing heat buildup
What actually causes this:
Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.
First Thing to Check
Clean the lint screen thoroughly and make sure the exhaust vent path is clear.
Parts Involved
How to Fix
- 1
1. Check for a clogged lint screen
- 2
2. Check if the vent system is restricted
- 3
3. Measure thermistor 2 resistance
- 4
4. If thermistor resistance is out of range, replace the thermistor
This Error Applies To
Samsung DVE45T6020 Series Dryers (2020) (2020–present)