Error Code tC5
A secondary temperature sensor is giving bad readings
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC5
What This Means
Clogged lint screen restricting airflow; Restricted vent system; Thermistor 2 resistance out of range (open or shorted)
What actually causes this:
Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.
First Thing to Check
Clean the lint screen thoroughly and make sure the exhaust vent path is clear.
Parts Involved
How to Fix
- 1
1. Check and clean the lint screen
- 2
2. Inspect the exhaust vent system for restrictions or blockages
- 3
3. Measure thermistor 2 resistance: should be 238.231KOhm at 25C (77F) — Yellow wire Pin 2 to White wire Pin 7
- 4
4. If thermistor resistance is out of range, replace the thermistor
Parts Commonly Needed for This Error
OEM part numbers confirmed by retailers
This Error Applies To
Samsung DVE52M8650 Series Dryers
Related Error Codes
The dryer's internal parts aren't communicating properly
A button on the control panel is stuck or shorted
Your dryer is getting the wrong type of electrical power
The door switch isn't working properly
The dryer thinks the door is open while running
Your dryer is getting the wrong voltage from the outlet
Your dryer's temperature sensor isn't reading correctly
Your dryer isn't heating properly or is overheating