Samsung Dryers

Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Clogged lint screen restricting airflow and causing abnormal temperature readings; Restricted vent system causing heat buildup; Thermistor 1 resistance out of range (open or shorted)

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

Thermistor 1 (Temperature Sensor)Lint Screen

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Inspect the exhaust vent system for restrictions or blockages

  3. 3

    3. Measure thermistor resistance: should be 10K ohm at 25 deg C (77 deg F)

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

This Error Applies To

Samsung DVE53BB890 Series Dryers

Service manual exact match: DVG53BB8900TService manual exact match: DVE53BB8900DService manual exact match: DVG53BB8900DService manual exact match: DVE53BB8900TA3Service manual exact match: DVG53BB8900TA3Service manual exact match: DVE53BB8900DA3Service manual exact match: DVG53BB8900DA3Service manual exact match: DVE53BB8900TAC+2 more