Error Code C-70
Steam temperature sensor circuit is open
Moderate
Address soon - your appliance may not work properly
Also displayed as: C-70
What This Means
Steam sensor connector loose at main PCB; Steam sensor connector loose at sensor; Damaged temperature sensor; Main PCB failure
What actually causes this:
Steam sensor wire broken, connector loose, or sensor failed in steam mode
First Thing to Check
Check steam sensor connector at main PCB is fully inserted
Parts Involved
How to Fix
- 1
Check connector at main PCB is inserted
- 2
Check connector at sensor is inserted
- 3
Inspect connectors for bent or corroded pins
- 4
If connectors are secure, replace temperature sensor
- 5
If problem persists, replace main PCB
This Error Applies To
Samsung DOB30M977 Series Ovens & Ranges (2017) (2017–present)
Related Error Codes
Touch panel control communication failure
PCB temperature sensor open or short circuit
Cooling fan motor malfunction
Oven temperature sensor circuit is open
PCB overheating - internal temperature critically high
Oven overheating - internal temperature critically high
Meat probe sensor short circuit detected
Steam drain system not working - water remains after cycle