Error Code C-70
Steam system temperature sensor open or short circuit
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-70
What This Means
Steam sensor connector disconnected at main PCB; Steam sensor connector disconnected at sensor; Faulty temperature sensor in steam system; Main PCB failure
What actually causes this:
Loose steam sensor connector or failed sensor element
First Thing to Check
Inspect and reseat steam sensor connector; verify sensor harness continuity
Parts Involved
How to Fix
- 1
Check whether connector at the main pcb has been inserted
- 2
Check whether connector at the sensor has been inserted
- 3
Check sensor operation in steam mode
- 4
Check main PCB for damage or loose components
This Error Applies To
Samsung DOP36M94DL Series Ovens & Ranges
Related Error Codes
Temperature sensor open circuit detected
PCB internal temperature abnormally high or sensor shorted
Probe temperature sensor has short circuit
Temperature regulation failure causing excessive oven temperature
Inter-PCB communication link failure detected
Touch screen panel communication with main control board lost
Door locking mechanism failed to engage or disengage
Main PCB internal temperature sensor failed