Error Code E-dE
Oven partition divider switch is not responding
Moderate
Address soon - your appliance may not work properly
Also displayed as: E-dE
What This Means
Loose or disconnected partition switch harness; Failed partition switch element; Abnormal partition switch resistance; Main PCB CN401 connector issue; Main PCB failure
What actually causes this:
Loose connector, failed switch, or PCB issue
First Thing to Check
Check partition switch harness is connected to CN401 on main PCB
Parts Involved
How to Fix
- 1
Disconnect power and open back cover
- 2
Check harness connected to partition switch
- 3
Measure partition switch resistance - should be normal value
- 4
Verify CN401 connector on main PCB is properly seated
- 5
Test harness continuity from switch to main PCB
This Error Applies To
Samsung NE58F9710W Series Ovens & Ranges (2013) (2013–present)
Related Error Codes
Main and sub control boards cannot communicate
Keypad circuit short detected
Meat probe is shorted or has short circuit
Keypad has a short circuit
Touch control panel is not communicating with sub board
Touch control communication failure
Temperature sensor circuit is broken open
Temperature sensor wires are shorted together