Samsung Ovens & Ranges2019–present

Error Code C-30

PCB temp sensor opened - Temperature sensor circuit open on control board

Moderate

Address soon - your appliance may not work properly

What This Means

NTC temperature sensor on PCB is open circuit; Damaged sensor connections; Defective main PCB

How to Fix

  1. 1

    Disconnect power and open back cover

  2. 2

    Remove PCB Main from holder

  3. 3

    Measure NTC sensor (located on backside of PCB) resistance (should read 24-38 ohms at room temperature)

  4. 4

    If resistance is infinite or out of range, replace PCB Main

This Error Applies To

Samsung NE59J3420S Series Ovens & Ranges (2019) (2019–present)

Service manual exact match: NE59*432***Service manual exact match: NE59J3420SSService manual exact match: NE59M3420SSService manual exact match: NE59J3421Service manual exact match: NE59J3421SS