PCB temp sensor opened - Temperature sensor circuit open on control board
Moderate
Address soon - your appliance may not work properly
What This Means
NTC temperature sensor on PCB is open circuit; Damaged sensor connections; Defective main PCB
How to Fix
- 1
Disconnect power and open back cover
- 2
Remove PCB Main from holder
- 3
Measure NTC sensor (located on backside of PCB) resistance (should read 24-38 ohms at room temperature)
- 4
If resistance is infinite or out of range, replace PCB Main