Error Code C0
Top Sensor Open Error (Cooktop)
Moderate
Address soon - your appliance may not work properly
What This Means
Defective sensor; Misplaced wires; Defective PCB; A/D value over 252; Ambient temperature below -10°C
How to Fix
- 1
Check if sensor is connected
- 2
Connect sensor if disconnected
- 3
Check sensor wire for damage
- 4
Check sensor housing insertion in PCB connector
- 5
Measure sensor real resistance (check for open circuit)
- 6
Replace sensor if defective
- 7
Replace main PCB if sensor tests normal
- 8
Wait for temperature to rise above -10°C if cold
This Error Applies To
Samsung NE63B8611 Series Ovens & Ranges
Related Error Codes
Power connection installed improperly
Top Sensor Short Error (Cooktop)
Over Temperature Error (Cooktop)
IGBT Sensor Open/Short Error
Communication Error between Main and Inverter Module
Oven sensor opened (over 2950 Ohms)
Door locking information/malfunction
Oven heating over - temperature exceeds safe limits