Samsung Ovens & Ranges2020–present

Error Code C-72

Drain system problem - Water level sensor senses water remaining after maximum draining time

Moderate

Address soon - your appliance may not work properly

What This Means

Ground wire disconnected on steam generator; Pump motor not operating; Pump motor wire connection loose; Main PCB failure

How to Fix

  1. 1

    Check the ground wire on the steam generator

  2. 2

    Check the pump motor operation and wire connection

  3. 3

    Replace the Main PCB if problem persists

This Error Applies To

Samsung NV51K6650 Series Ovens & Ranges (2020) (2020–present)

Service manual exact match: NV51K6650S*Service manual exact match: NV51K6650D*