Error Code C-72
Drain system problem - Water level sensor senses water remaining after maximum draining time
Moderate
Address soon - your appliance may not work properly
What This Means
Ground wire disconnected on steam generator; Pump motor not operating; Pump motor wire connection loose; Main PCB failure
How to Fix
- 1
Check the ground wire on the steam generator
- 2
Check the pump motor operation and wire connection
- 3
Replace the Main PCB if problem persists
This Error Applies To
Samsung NV51K6650 Series Ovens & Ranges (2020) (2020–present)
Related Error Codes
Temp probe sensor is shorted when oven is operating
PCB temp sensor is open or shorted when oven is operating
PCB temperature rises abnormally high
Steam sensor is open or shorted when steam mode is on
Cooling motor is operating abnormally
Door lock is mispositioned
Internal temperature rises abnormally high
Keys are shorted