Error Code C-30
PCB temperature sensor malfunction
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-30
What This Means
NTC sensor open circuit; NTC sensor short circuit; Broken solder joint on PCB; Damaged sensor component
What actually causes this:
Failed thermistor component or damaged solder connection on main PCB
First Thing to Check
Visually inspect NTC200 sensor for damage; measure resistance (3200Ω at room temperature)
Parts Involved
How to Fix
- 1
Disconnect electrical power
- 2
Remove back cover
- 3
Check NTC200 sensor status for breaks or poor soldering
- 4
Measure NTC sensor resistance (should be 3200Ω at room temperature)
This Error Applies To
Samsung NV51M9770S Series Ovens & Ranges (2020) (2020–present)
Related Error Codes
Safety interlock triggered - excessive temperature detected
Display/touch panel communication failure
Oven temperature control failure - overheating
Temperature probe circuit fault
Steam generation temperature sensor circuit open
Keypad control circuit short circuit
Steam drain pump circuit malfunction
Oven temperature sensor malfunction