Error Code C-F0
Main and Sub processor communication link failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-F0
What This Means
Disconnected wire harness between Main and Sub PCB; Outdated software version on Main or Sub PCB; Loose connector at CN600 (Main) or CNS200 (Sub)
What actually causes this:
Loose harness connector, damaged wiring, or incompatible firmware versions
First Thing to Check
Verify wire harness connected between Main and Sub PCB; check HASS software version
Parts Involved
How to Fix
- 1
Check wire harness connection at Main PBA CN600 and SUB PBA CNS200
- 2
Verify wire harness is completely connected
- 3
Check Main-Sub PCB software version via HASS
- 4
Determine if software is latest version
This Error Applies To
Samsung NV51M9770S Series Ovens & Ranges (2020) (2020–present)
Related Error Codes
Steam drain pump circuit malfunction
Safety interlock triggered - excessive temperature detected
Display/touch panel communication failure
Oven temperature control failure - overheating
Temperature probe circuit fault
Steam generation temperature sensor circuit open
Keypad control circuit short circuit
Oven temperature sensor malfunction