Error Code C-d1
Door lock is mispositioned
Moderate
Address soon - your appliance may not work properly
What This Means
Harness not connected with door lock switch and motor; Door lock motor resistance out of range; Incorrect voltage to door lock motor; Door locking switch not working normally; Circuit breaker tripped during door lock operation
How to Fix
- 1
Disconnect power; check whether harness has been connected with door lock switch and motor
- 2
Confirm resistance value of door lock motor is correct: normal value 1600-2200 ohms at room temperature
- 3
Operate door lock; measure voltage at plug supplying power to door lock motor (normal: AC 120V)
- 4
Check whether door locking switch is working normally
- 5
Check micro switch: COM-NC should be closed when door is unlocked
- 6
Measure resistance of CN201 on Main PCB (COM-NO: infinite ohms at room temperature); COM is black wire, NO is yellow wire
- 7
Replace micro switch or lock motor if faulty
- 8
Repair or replace damaged harness
- 9
Replace main PCB if required
This Error Applies To
Samsung NV51R5511D Series Ovens & Ranges (2019) (2019–present)
Related Error Codes
Power connection is installed improperly
PCB temperature rises abnormally high
Oven sensor is open when the oven is operating
Keys are shorted
Communication between Main and Sub PCB is interrupted
Upper cooling motor is operating abnormally
Communication between Main and Touch PCB is interrupted
PCB temp sensor is open or shorted when the oven is operating