Error Code C-30
PCB internal sensor opened (over 3900 ohms) or shorted
Moderate
Address soon - your appliance may not work properly
What This Means
Faulty oven temperature sensor; Faulty main PCB internal sensor circuit; Loose or disconnected harness at PCB connectors CNP205, CNP206
How to Fix
- 1
Disconnect power and remove upper rear cover panel
- 2
Measure PCB sensor resistance (normal: 3900 ohms at room temperature)
- 3
Measure oven sensor resistance (normal: 1080 ohms at room temperature)
- 4
Check oven sensor harness connections at PCB
- 5
Ensure harness connectors are fully seated in CNP205 and CNP206 on PCB
- 6
Replace oven temperature sensor if out of spec
- 7
Replace main PCB if internal sensor circuitry is faulty
This Error Applies To
Samsung NX58M66 Series Ovens & Ranges
Related Error Codes
Main PCB to Touch module communication error
Oven overheating — oven temperature exceeds 650°F (343°C) in any cooking function except self-clean
PCB ambient temperature too high — temperature around PCB is excessive
Shorted keypad key detected
Oven temperature sensor open (resistance over 2950 ohms) or shorted (resistance under 930 ohms)
Door locking mechanism error — door lock motor or switch malfunction