Main to Sub PCB communication error - Continuous communication failure between Main PCB and Sub display/fan control PCB

Moderate

Address soon - your appliance may not work properly

What This Means

Disconnected communication harness; Defective harness connector; Software version mismatch; Faulty Main PCB; Faulty Sub PCB

How to Fix

  1. 1

    Disconnect power and open back cover

  2. 2

    Verify harnesses are connected: Main CNS401 <-> Sub Display CN200

  3. 3

    Verify harnesses are connected: Main CN304 <-> Sub Fan Control CN500

  4. 4

    Check software versions by pressing Keep Warm + 3 for 3 seconds

  5. 5

    Expected versions: Main 1204, Sub Display 1204, Sub Fan Control 1201

  6. 6

    Reconnect all loose harnesses

  7. 7

    Replace Main or Sub PCB if versions do not match