Error Code 9
FlexZone compartment temperature sensor is broken or disconnected
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: CV-Sensor Error
What This Means
CV sensor disconnected or slipped from housing; Wire cut or damaged; Wire short circuit; Sensor failure from age
What actually causes this:
Flex zone sensor failure or wiring damage
First Thing to Check
Verify 12-pin housing connector is fully engaged
Parts Involved
How to Fix
- 1
Inspect FreshZone+ compartment sensor mounting
- 2
Check connector seating at control board
- 3
Measure voltage across sensor terminals if accessible
- 4
Verify no visible water damage on sensor
This Error Applies To
Samsung BRF425200A Series Refrigerators (2017) (2017–present)
Related Error Codes
Cocktail ice maker is not producing ice
Pantry compartment temperature sensor is not working
Standard ice maker position or operation sensor is not responding
Cocktail ice maker sensor is not responding
Ice maker water line heater is broken or disconnected
FlexZone compartment is not maintaining proper temperature
Rear cabinet heater element is broken or disconnected
Right compressor power module has detected a fault