Samsung Refrigerators2017–present

Error Code 83

The compressor has an abnormal electrical current signature

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 83

What This Means

Compressor wire connections loose; Inverter PCB cold solder joints; Short circuit in power stage; Compressor motor bearing wear; Refrigerant issues

What actually causes this:

A loose wire connection or compressor bearing wear is causing electrical problems

First Thing to Check

Check all wire connections to the compressor for looseness or corrosion

Parts Involved

Compressor MotorInverter PCBPower RelayWire Harness

How to Fix

  1. 1

    1. Check compressor wire connections for loose terminals

  2. 2

    2. Check inverter PCB soldering for cold joints

  3. 3

    3. Check for any short circuits in inverter power stage

  4. 4

    4. Measure compressor supply voltage — normal: AC 115V

  5. 5

    5. Check compressor bearing movement (motor should have slight play, not lock)

This Error Applies To

Samsung DRZ18980R Series Refrigerators (2017) (2017–present)

Service manual exact match: DRZ18980R/DAService manual exact match: DRZ18980L/DAService manual exact match: DRZ24980R/DAService manual exact match: DRZ24980L/DAService manual exact match: DRZ30980R/DAService manual exact match: DRZ30980L/DAService manual exact match: DRZ30990R/DAService manual exact match: DRR24980R/DA+2 more