Samsung Refrigerators2024–present

Error Code 43C

The main board can't communicate with the compressor inverter

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 43C

What This Means

Inverter communication wire disconnection; Inverter connector contact error; Defective Compressor Inverter PBA; Defective Main PBA; Soldering defect on PCB

What actually causes this:

The compressor control board connection is loose

First Thing to Check

The compressor won't run

Parts Involved

Main PBACompressor Inverter PBACommunication WireConnector

How to Fix

  1. 1

    1. Check compressor inverter communication connector

  2. 2

    2. Verify all connections are properly seated

  3. 3

    3. Inspect communication wires for damage or disconnection

  4. 4

    4. Use oscilloscope to verify communication signal

  5. 5

    5. Check PCB soldering quality on inverter board

  6. 6

    6. If connections normal, replace Main PBA

  7. 7

    7. If issue persists, replace Compressor Inverter PBA

This Error Applies To

Samsung RF2 Series Refrigerators (2024) (2024–present)

Service manual exact match: RF29DService manual exact match: RF23DService manual exact match: RF29DB9900Service manual exact match: RF23DB9900Service manual exact match: RF29DB9750Service manual exact match: RF23DB9750Service manual exact match: RF29DB9700Service manual exact match: RF23DB9700+2 more

Need more help with your Samsung refrigerators?