Error Code 82C
The compressor power control circuit failed
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 82C
What This Means
IPM internal circuit failure; IPM pin short-circuit; Gate driver malfunction; Defective Inverter PBA; Soldering defect on PCB
What actually causes this:
The inverter module has an internal failure
First Thing to Check
The compressor won't run at all
Parts Involved
How to Fix
- 1
1. Check PCB soldering on inverter part for cold solder joints
- 2
2. Look for any visible damage or burn marks on IPM
- 3
3. Check IPM pin connections for corrosion or bent pins
- 4
4. Measure DC voltage at IPM power input — should be 15V minimum
- 5
5. If IPM appears damaged, replace Inverter PBA
- 6
6. If soldering defective, repair or replace inverter PCB
This Error Applies To
Samsung RF2 Series Refrigerators (2024) (2024–present)
Related Error Codes
The proximity sensor hardware is broken
The freezer temperature sensor isn't reading correctly
The fridge temperature sensor isn't reading correctly
The humidity sensor isn't working properly
The Cool Select room temperature sensor is malfunctioning
The Cool Select room fan isn't working properly
The ice maker temperature sensor isn't working
The cubed ice maker has failed multiple times