Error Code COV

House electrical power is too high

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: COV LED blinks

What This Means

House voltage above 127V AC (North America) or 240V AC (Europe); Power surge from utility line; Voltage regulator failure; Defective main PCB

What actually causes this:

House voltage too high or power surge from utility

First Thing to Check

Check if other appliances are affecting power stability

Parts Involved

Main PCB Power SupplyPower Surge Protector

How to Fix

  1. 1

    1. Use multimeter to measure input power at wall socket

  2. 2

    2. Should be AC 110-127V or AC 220-240V depending on region

  3. 3

    3. Check for power surge conditions

  4. 4

    4. Check PCB bottom side soldering