Error Code CF
Compressor cooling fan is not working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: CF LED blinks
What This Means
Fan motor wire disconnected; Motor bearing seized; Control signal lost; Motor winding failure
What actually causes this:
Fan motor burned out or loose connector
First Thing to Check
Check if CN40 fan connector is fully seated
Parts Involved
How to Fix
- 1
1. Measure voltage at MAIN PCB CN40-11 to CN40-13
- 2
2. Voltage should be between 7V and 12V
- 3
3. Check fan motor connector seating
- 4
4. Verify fan rotation
This Error Applies To
Samsung RF22R7351 Series Refrigerators (2010) (2010–present)
Related Error Codes
Flex Zone compartment is too warm right now
Ice duct heater is not working
Freezer temperature sensor is broken or disconnected
Outside temperature sensor is not working
Ice storage room temperature sensor is not working
Flex Zone damper heater circuit is broken
Main board and compressor inverter board cannot communicate
Refrigerator temperature sensor is broken or disconnected