Error Code IDH
Ice duct heater is not working
Moderate
Address soon - your appliance may not work properly
Also displayed as: IDH LED blinks
What This Means
Heater element shorted; Thermostat failed; Wire connection loose; Bimetal open circuit
What actually causes this:
Heater element failed or loose connection
First Thing to Check
Unplug and check if CN20 connector is fully seated
Parts Involved
How to Fix
- 1
1. Disconnect MAIN PCB CN20 from board
- 2
2. Measure resistance between CN20-21 and CN20-23
- 3
3. Should read 63 ohms ±7%
- 4
4. 0 ohm indicates short, infinity indicates open
This Error Applies To
Samsung RF22R7351 Series Refrigerators (2010) (2010–present)
Related Error Codes
Flex Zone compartment is too warm right now
Freezer temperature sensor is broken or disconnected
Outside temperature sensor is not working
Ice storage room temperature sensor is not working
Flex Zone damper heater circuit is broken
Main board and compressor inverter board cannot communicate
Refrigerator temperature sensor is broken or disconnected
Flex-Zone temperature sensor is broken or disconnected