Error Code IRF
Ice room fan motor is not running
Moderate
Address soon - your appliance may not work properly
Also displayed as: IRF LED blinks
What This Means
Fan motor wire disconnected; Motor bearing seized; Control signal lost; Motor failure
What actually causes this:
Fan motor failed or loose connector
First Thing to Check
Check if ice room fan connector is fully connected
Parts Involved
How to Fix
- 1
1. Measure voltage at MAIN PCB CN20-22 to CN20-24
- 2
2. Voltage should be between 7V and 12V
- 3
3. Check fan connector seating
- 4
4. Verify fan operation
This Error Applies To
Samsung RF22R7351 Series Refrigerators (2010) (2010–present)
Related Error Codes
Flex Zone compartment is too warm right now
Ice duct heater is not working
Freezer temperature sensor is broken or disconnected
Outside temperature sensor is not working
Ice storage room temperature sensor is not working
Flex Zone damper heater circuit is broken
Main board and compressor inverter board cannot communicate
Refrigerator temperature sensor is broken or disconnected