Samsung Refrigerators2023–present

Error Code 7E

Cool Select Room temperature sensor is disconnected or failed

Moderate

Address soon - your appliance may not work properly

Also displayed as: 7E

What This Means

CV sensor connector at CN30 unseated; Open or shorted thermistor

What actually causes this:

The thermistor in the Cool Select Room drawer section has lost its connection or failed, so the board cannot regulate temperature in that compartment.

First Thing to Check

Remove the Cool Select Room drawers and inspect the sensor wire connector for secure seating.

Parts Involved

Cool Select Room thermistorMain PCB CN30 pins 8-9

How to Fix

  1. 1

    Measure voltage between Main PCB CN30 pins 8 and 9; should be within 4.1V–0.8V

  2. 2

    Inspect sensor connector behind Cool Select Room evaporator cover

This Error Applies To

Samsung RF23 Series Refrigerators (2023) (2023–present)

Service manual exact match: RF23K*Service manual exact match: RF23J*Service manual exact match: RF23J*/RF23K