Error Code COMP_IPM_SHUTDOWN
Inverter power module executed an emergency shutdown
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Inverter PBA LED blinks
What This Means
Inverter PCB soldering defect (short-circuited components); DC 15V output dropped below 13.5V; Compressor overcurrent; Refrigerant cycle overload
What actually causes this:
The inverter's power module detected a dangerous condition and shut itself down to prevent permanent damage.
First Thing to Check
Check that the condenser fan is running and the condenser coils are clean to ensure adequate cooling of the inverter.
Parts Involved
How to Fix
- 1
Check DC 15V output at ZD501: must be above 13.5V
- 2
Inspect inverter PCB for shorted components
- 3
Check compressor and refrigerant cycle
This Error Applies To
Samsung RF23BB89 Series Refrigerators (2023) (2023–present)