Error Code COMP_IPM_FAULT
Inverter power module has detected a fault
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Inverter PBA LED blinks
What This Means
IPM internal overcurrent or overheat; Inverter PCB soldering defect; DC 15V supply dropped below 13.5V; Compressor or refrigerant cycle issue
What actually causes this:
The power module driving the compressor motor has detected an overload or fault, typically caused by a failing compressor or electrical fault on the board.
First Thing to Check
Check the machine compartment is ventilated and the condenser fan is running, as overheating can trigger IPM faults.
Parts Involved
How to Fix
- 1
Check DC 15V at ZD501: must be above 13.5V
- 2
Check inverter PCB for soldering shorts
- 3
Check compressor and refrigerant cycle