Error Code PC-Ch
Display panel lost communication with the main control board
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: PC - Ch
What This Means
Communication failure between display panel MICOM and main MICOM; Damaged or disconnected wiring harness; Defective panel PCB or main PCB
What actually causes this:
A loose connector or failed circuit board is preventing the display from talking to the main board.
First Thing to Check
Reseat the wire harness connector between the panel and main board.
Parts Involved
How to Fix
- 1
Check wiring connections between panel and main PCB
- 2
Inspect connector insertion at freezer upper-hinge
- 3
Replace Main and Panel PCB if wiring is normal
This Error Applies To
Samsung RF25HMEDBS Series Refrigerators (2013) (2013–present)
Related Error Codes
Display panel cannot communicate with main control board
The display and main board cannot communicate with each other
The control board has detected an option configuration error
Control board option configuration error detected
Freezer temperature has gone too high
Refrigerator temperature has risen too high