Error Code 52E
Fridge compressor inverter power module detected a fault
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 52E
What This Means
IPM (SLA6805M) defective on R Room inverter PCB; Overcurrent condition; Short in compressor winding
What actually causes this:
IPM on R Room inverter board failed, typically from overcurrent or a voltage spike.
First Thing to Check
Inspect the R Room inverter PCB for visible burn marks or damaged components near the IPM module.
Parts Involved
How to Fix
- 1
Inspect R Room inverter PCB IPM SLA6805M for damage
- 2
Check SPM freewheeling diode voltage values per page 62 diagram
- 3
Verify compressor winding resistance