Error Code 52Er
Main board has lost communication with the Wi-Fi module
Moderate
Address soon - your appliance may not work properly
Also displayed as: 52Er
What This Means
Wi-Fi module connector loose on LCD PBA (CN602); Wi-Fi/BT module failure; LCD PBA failure
What actually causes this:
The Wi-Fi module connector is loose, or the module itself has failed.
First Thing to Check
Reseat the Wi-Fi module connectors CN602 and CN603 on the LCD PBA.
Parts Involved
How to Fix
- 1
Check LCD PBA connector CN602 and CN603 are properly inserted
- 2
Verify 5V is present at CN603 PIN 7(GND) to PIN 9(5V)
- 3
Replace Wi-Fi/BT module if power is good but error persists
This Error Applies To
Samsung RF59A7670 Series Refrigerators (2022) (2022–present)
Related Error Codes
Interior humidity sensor is faulty or not getting power
The main control board and display panel board have lost communication
Fridge compartment temperature sensor is faulty or disconnected
Machine compartment condenser fan has stopped working
Internal I/O chip on the main board has stopped communicating
External ambient temperature sensor is faulty or disconnected
Freezer defrost heater or related safety component has failed
Freezer fan motor has stopped working or lost its feedback signal