Samsung Refrigerators

Error Code 41E

MICOM serial communication protocol failure between control boards

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 41 E

What This Means

No response from panel MICOM for 10+ seconds; Loose connector between main and panel PCB; Defective panel PCB; Defective main PCB

What actually causes this:

Defective PCB communication IC, broken wire in communication harness, or power supply failure to panel

First Thing to Check

Disconnect and reconnect panel PCB connector at main board

Parts Involved

Main PCB (DA92-00624*)Panel PCBCommunication wiring

How to Fix

  1. 1

    Requires oscilloscope to diagnose communication protocol issues

  2. 2

    Check wiring between main PCB and panel PCB

  3. 3

    Verify 5V power is supplied to panel PCB

This Error Applies To

Samsung RH25H5613S Series Refrigerators