Samsung Refrigerators

Error Code 15

Compressor power module overheating and shutting down

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 96

What This Means

IPM temperature exceeds thermal limit; Inverter operating at excessive current; Inadequate heatsink cooling; Ambient temperature very high; Continuous operation without cooling

What actually causes this:

Inverter getting too hot from continuous operation

First Thing to Check

Ensure refrigerator has good air circulation around it

Parts Involved

Inverter PCBIPM DeviceHeatsink

How to Fix

  1. 1

    Allow compressor to cool for 15-30 minutes

  2. 2

    Check inverter PCB heatsink for dust or blockage

  3. 3

    Verify ambient temperature is not excessive

  4. 4

    Check for continuous operation without rest

  5. 5

    Measure IPM device temperature with IR thermometer

This Error Applies To

Samsung RR39M73 Series Refrigerators