Error Code 81E
Compressor motor will not start
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 81E
What This Means
Short between compressor terminals; IPM voltage below 13.5V; Short between IPM pins; Defective compressor
What actually causes this:
Compressor motor winding shorted, refrigerant lines frozen, or IPM power supply fails
First Thing to Check
Measure voltage at IPM module, should be 13.5V or higher
Parts Involved
How to Fix
- 1
Check voltage at IPM (Inverter Power Module) - should be above 13.5V DC
- 2
Check for short between compressor motor terminals
- 3
Check for short between IPM pins 1-33
- 4
Verify compressor cycle pressure and lines
- 5
Check for refrigerant lines blocked
This Error Applies To
Samsung RS22HDHPN Series Refrigerators (2013) (2013–present)
Related Error Codes
Fridge sensor failure or wiring issue
Freezer temperature critically high
Compressor drawing excessive or abnormal current
Ice maker positioning failure
Ambient temperature sensor failure
Freezer fan motor failure or feedback signal issue
Freezer defrost sensor failure
Fridge defrost sensor failure