Samsung Refrigerators2014–present

Error Code 81E

Compressor motor won't start

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 81 E

What This Means

Motor winding short circuit (U,V,W); IPM pins short on Inverter PBA; IPM operating voltage below 13.5V; Compressor mechanical restriction

What actually causes this:

The compressor is either stuck mechanically, not receiving power, or the control board can't signal it.

First Thing to Check

Check if the compressor makes any humming sound when you activate forced operation mode.

Parts Involved

CompressorInverter PCBIPM (FNE41060)

How to Fix

  1. 1

    Activate forced operation mode

  2. 2

    Check IPM pins 1-26 for shorts on Inverter PBA

  3. 3

    Measure IPM operating voltage (should be DC 13.5V or higher)

  4. 4

    Check compressor RPM cycle operation

This Error Applies To

Samsung RS25H51 Series Refrigerators (2014) (2014–present)

Service manual exact match: RS25H5121BC/AAService manual exact match: RS25H5111WW/AAService manual exact match: RS25H5111SR/AAService manual exact match: RS25H5121SRService manual exact match: RS25H5111BCService manual exact match: RS25H5121WWService manual exact match: RS25H5113SLService manual exact match: RS25H5111SR+2 more

Need more help with your Samsung refrigerators?