Samsung Refrigerators2010–present

Error Code 03

Compressor fails to operate or protection activated

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Right - ③ LED ON

What This Means

IPM pins shorted (U,V,W); Abnormal current detected at compressor; Low input voltage; Inverter PBA fault; Compressor restriction

What actually causes this:

Power surge damages IPM chip or wiring harness becomes loose

First Thing to Check

Verify AC input voltage at service plug is within spec

Parts Involved

Compressor AssemblyInverter PCBIPM (FNE41060)

How to Fix

  1. 1

    Check IPM pins for short circuit (pins #1-26 on Inverter PBA)

  2. 2

    Measure IPM operating voltage (should be > DC 13.5V)

  3. 3

    Check compressor wire connections (U, V, W)

  4. 4

    Verify input voltage: AC 53V min for 115V input or AC 106V min for 220V

This Error Applies To

Samsung RS25J50 Series Refrigerators (2010) (2010–present)

Service manual exact match: RS25J500DSR/BYService manual exact match: RS25J500DSG/AAService manual exact match: RS25J500DBC/BYService manual exact match: RS25J500DWW/AAService manual exact match: RS25J5008SP/EMService manual exact match: RS25J50****Service manual exact match: RS25J500DSRService manual exact match: RS25J500DBC+2 more