Samsung Refrigerators2017–present

Error Code R3

Compressor has failed and stopped operating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: R3 (R-ROOM STEP 3 LED blinking)

What This Means

Compressor internal mechanical failure; IPM fault on inverter PCB (IGCM04G60HA); Short between compressor U, V, W phases (CN102); Short among IC3 pins #1 to #24 on inverter PCB; DC operating voltage dropped below 13.5V

What actually causes this:

Compressor mechanical failure, inverter PCB IPM fault, or low DC bus voltage

First Thing to Check

Check DC 16V output at inverter PCB and inspect CN102 compressor wiring for shorts

Parts Involved

Compressor (MSV4A1AL1R/TT3 BLDC)Inverter PCBIPM (IGCM04G60HA)CN102

How to Fix

  1. 1

    Check inverter PCB LED blink pattern to identify specific sub-fault

  2. 2

    Check compressor wire connections at CN102

  3. 3

    Check soldering status of inverter PCB for short-circuited parts

  4. 4

    Check if DC 16V output is below 13.5V

  5. 5

    Check compressor and refrigerant cycle for restriction or blockage

  6. 6

    Wait 5 minutes after fault — compressor enters standby, RPM signals ignored

This Error Applies To

Samsung RT21M6215 Series Refrigerators (2017) (2017–present)

Service manual exact match: RT18M6213**Service manual exact match: RT18M6***Service manual exact match: RT21M6211**Service manual exact match: RT18M6114**Service manual exact match: RT18M6215**Service manual exact match: RT21M6215**Service manual exact match: RT18M6211**Service manual exact match: RT21M6***