Error Code 4C2
The incoming water is too hot for the delicate cycle selected
Moderate
Address soon - your appliance may not work properly
Also displayed as: 4C2
What This Means
Water temperature sensed higher than 50 degrees C in Wool or Lingerie course; Hot water supply connected to cold water inlet; Water heater temperature set too high
What actually causes this:
The hot and cold water hoses are swapped, or the water heater is set too high
First Thing to Check
Check that the hot and cold water hoses behind the washer are connected to the correct inlets
Parts Involved
How to Fix
- 1
1. Check that the hot and cold water hoses are connected to the correct inlets
- 2
2. Verify the home water heater is set to 120 degrees F or lower
- 3
3. Run cold water at a nearby faucet for one minute before starting the cycle
- 4
4. If the error persists, check the temperature sensor