Error Code AC6
The motor controller board lost communication with the main board
Moderate
Address soon - your appliance may not work properly
Also displayed as: AC6
What This Means
Signals between Inverter PBA and main PBA not sensed; Incorrect or loose connections between Inverter PBA and main PBA; Inverter PBA faulty soldering
What actually causes this:
A connector between the inverter board and main board came loose or a board failed
First Thing to Check
Unplug the washer for 5 minutes and plug it back in to reset
Parts Involved
How to Fix
- 1
1. Check the connector connections between the Inverter PBA and main PBA carefully
- 2
2. Check for incorrect or loose connections
- 3
3. Remove the Inverter PBA and check for any faulty soldering
- 4
4. Check if the status LEDs around the Micom are normal
- 5
5. Replace the communication circuit between the Micom and Micom if there are defects
This Error Applies To
Samsung WD53DBA900HZA1 Series Washers (2024) (2024–present)
Related Error Codes
The humidity sensor inside the dryer is not reading correctly
The automatic door-opening feature is not working after a cycle ends
A dryer button is being registered as stuck or continuously pressed
The heat pump compressor motor has failed or lost its connection
A temperature sensor on the refrigerant line is reading incorrectly
A temperature sensor on the evaporator inlet is reading incorrectly
A temperature sensor on the evaporator outlet is reading incorrectly
A temperature sensor on top of the compressor is reading incorrectly