Error Code C-20
Temperature sensor circuit is open - no resistance reading possible
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-20
What This Means
Temperature sensor disconnected; Sensor connector not fully inserted; Sensor wire broken; Temperature sensor failure
What actually causes this:
Loose connector, broken wire, or failed temperature sensor
First Thing to Check
Reseat temperature sensor connector at Main PCB (CN320 or CN600 pin 10)
Parts Involved
How to Fix
- 1
Check connector at Main PCB
- 2
Check connector at temperature sensor
- 3
Measure sensor resistance at room temperature (should be ~1080 ohms)
- 4
Verify wire continuity
Other Error Codes for NQ70M9770D
Temperature sensor internal to Main PCB is not functioning
Keypad short circuit detected
Temperature sensor reading exceeds safe operating threshold
Door lock mechanism malfunction or misalignment
Meat probe sensor circuit shows abnormally low resistance
Bake heating element not energizing during self-test
Main control board temperature sensor reads excessive heat
Partition configuration changed during active cooking cycle