LG LMXS28626SRefrigerator

Error Code dS F

Defrost Sensor Error — short or open circuit on defrost/evaporator sensor

Moderate

Address soon - your appliance may not work properly

Also displayed as: dS F

How to Fix

  1. 1

    Press Ice Plus + Freezer button simultaneously to read error within 3 hours of occurrence.

  2. 2

    Check for loose or disconnected connector between Main PCB, defrost controller, and sensor.

  3. 3

    If connector is disconnected, reconnect or repair it.

  4. 4

    Measure sensor resistance at CON7 pin 19 to pin 22. If resistance is 0 Ω (short) or infinite (open), replace the sensor.

  5. 5

    If resistance is in range, cross-reference: -5°C=38kΩ, 0°C=30kΩ, 5°C=24kΩ, 10°C=19.5kΩ, 15°C=16kΩ.

  6. 6

    If temperature/resistance values are normal, explain normal operation to customer.

  7. 7

    If abnormal after sensor checks out OK, replace Main PCB.