Error Code E gF
Defect of flow meter / lack of water supply
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Verify water supply is turned on and water pressure is adequate.
- 2
Check flow sensor connection — flow sensor is in machine room.
- 3
Measure flow sensor resistance: Red wire to Black wire should read 4–30 kΩ. If out of range or OL/short, replace flow sensor.
- 4
Check water valve pilot solenoid resistance: 69.06–76.33 Ω. Replace valve if out of specification.
- 5
Check water line for kinks or damage.
- 6
If all components check OK and water supply is confirmed, explain to customer.
Other Error Codes for LRYKC2606V
Defect of UVC LED / PSD sensor
PSD sensor error
Defect of refrigerator sensor
Defect of room temperature (RT) sensor
Defect of freezer craft ice maker sensor
Defect of ice maker kit (in-door icemaker motor malfunction)
Defect of Mini Cubed ice maker kit
Defect of pantry sensor