Samsung RF22A4110SRRefrigerator
Error Code 60
Compressor will not start
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: F/R
What This Means
Short circuit between compressor phases; IPM (Inverter Power Module) voltage low; Inverter gate driver failure; Compressor winding shorted
What actually causes this:
Compressor winding is shorted or inverter board is broken
First Thing to Check
Listen for relay clicking sound when power is applied
Parts Involved
Inverter PCBCompressor Assembly (NN34M9112ARTT3)
How to Fix
- 1
1. Check voltage at TD505: should be DC 15V
- 2
2. Check voltage at C125: should be DC 5V
- 3
3. Measure compressor winding continuity
- 4
4. Check IPM voltage output
- 5
5. Activate manual operation mode to test